title: "Type A sleeve leak on Colonial Line 1, Huntersville, North Carolina (CPF 2-2021-005-NOPSO)"
description: "2020 gasoline leak on Colonial Line 1 in Huntersville, NC, from corrosion fatigue under a 2004 Type A sleeve installed over a shallow dent."
section: case-studies
updated: 2026-11-25
canonical: https://pipelinerepairs.com/case-studies/cs-03-type-a-sleeve-leak-on-colonial-line-1-huntersville-north-carolina-cpf-2-/
markdown: https://pipelinerepairs.com/articles/case-studies/cs-03-type-a-sleeve-leak-on-colonial-line-1-huntersville-north-carolina-cpf-2-.md
---

# Type A sleeve leak on Colonial Line 1, Huntersville, North Carolina (CPF 2-2021-005-NOPSO)

In short. 2020 gasoline leak on Colonial Line 1 in Huntersville, NC, from corrosion fatigue under a 2004 Type A sleeve installed over a shallow dent.

Source: PHMSA, Office of Pipeline Safety, Southern Region (2020). Account type: Independent regulatory record.

On 14 August 2020, residents reported a gasoline leak near Huntersville, North Carolina, on Colonial Pipeline Line 1. The source was a Type A sleeve installed in 2004 over a shallow dent. Water was present under the sleeve, and laboratory work pointed to corrosion fatigue as the main way the crack grew through the wall. Colonial first put a Type B sleeve over the failed Type A repair and restarted the 40-inch X60 line, then later cut the section out for analysis. The reported spill volume was raised to 28,571 barrels. PHMSA's March 2021 notice treated Type A sleeves as a system-wide integrity issue, not a one-off defect.

## Method

Type A steel sleeve (failed in service), followed by a Type B pressure-containing sleeve installed over the Type A sleeve as a temporary repair, then a cut-out and pipe replacement for laboratory analysis.

## Defect

Shallow dent originally reinforced by a Type A sleeve in 2004; a through-wall crack later developed in the anomaly. Metallurgical analysis identified corrosion fatigue as the primary crack-growth mechanism, with water present under the sleeve.

## Pipe

Colonial Line 1: 40-inch, 0.312-inch wall, API 5L X60, DSAW seam, coal-tar coating, manufactured in 1978 by Bethlehem Steel. MOP 673 psig. Operating pressure at the estimated time of failure was 183 psig. Gasoline service.

## Outcome

Colonial's reported release volume was revised from 75 barrels to 6,490 barrels and then to 28,571 barrels (about 1.2 million gallons) of gasoline. The leak was in the Oehler Nature Preserve. After a temporary Type B oversleeve, the company cut out the failed section and sent it for independent metallurgical analysis. PHMSA proposed a system-wide Type A sleeve inventory and remediation program.

This account is taken from a public regulatory or investigative record.

Dates: Leak reported 14 August 2020. Temporary Type B oversleeve installed and the line restarted 19 August 2020. Failed pipe cut out 10 November 2020. Notice of Proposed Safety Order issued 29 March 2021.

Maker named in the source: Sleeve manufacturer not named.

## Sources

- [Type A sleeve leak on Colonial Line 1, Huntersville, North Carolina (CPF 2-2021-005-NOPSO)](https://primis.phmsa.dot.gov/enforcement-documents/22021005NOPSO/22021005NOPSO_Notice%20of%20Proposed%20Safety%20Order_03292021_%2820-188854%29_text.pdf) — PHMSA, Office of Pipeline Safety, Southern Region