# Insertion valves and line stops after a sheared 8-inch valve, Covington, Ohio

In short. Emergency insertion valves and line stops on 4- to 12-inch municipal mains to isolate a sheared 8-inch valve without shutting down service.

Source: Hydra-Stop (Pentair), describing work by Rangeline for the Village of Covington (2025). Account type: Vendor account.

On the first day of a 90-day project to replace water, sewer, and storm mains through downtown Covington, Ohio, a crew snagged an unknown service and blew the top off an 8-inch valve. Rangeline installed nine insertion valves and two line stops on 4- to 12-inch pipe so the damaged valve and work zones could be isolated. The village and contractor reported that water loss was brought under control, service was largely maintained, and work resumed the same day. The case is vendor marketing and is a municipal water job, included because line-stop and insertion-valve practice is often requested alongside oil-and-gas hot tapping.

## Method

Nine Insta-Valve 250 insertion valves and two HSF 250 line stops, on 4- to 12-inch water pipe, to isolate a blown valve and other work areas

## Defect

An unknown water service was snagged on day one of a main-replacement job and sheared the top off an 8-inch valve, sending water 10 to 12 inches into the street

## Pipe

Municipal water system, Village of Covington, Ohio. Pipes from 4 to 12 inches. Pressures not stated.

## Outcome

The vendor and contractor say the insertion valves and line stops stopped the uncontrolled loss, kept service on, and let construction continue the same day, while leaving permanent control points in the system. This is a water-distribution case, not oil or gas transmission.

Schedule, cost, and service-life figures in this note are the publisher’s claims. They were not checked against an operator record or a laboratory report.

Dates: PDF footer is copyright 2025. The project year is not otherwise stated.

Maker named in the source: Hydra-Stop.

## Sources