# Double-hump girth-weld sleeve on a 26-inch Kentucky gas line

In short. A custom 40.5-inch sleeve covering corrosion next to two closely spaced girth welds, where a standard half-sole would not fit.

Source: Allan Edwards field account, written by Allan Edwards (inquiry dated March 2023; no downloadable PDF).

A 26-inch natural gas line in Kentucky had corrosion near two girth welds that were too close for a standard half-sole or a single-hump girth-weld sleeve. The repair was a custom 40-1/2-inch “double hump” sleeve, with a custom drawing, modified rolling, and specialized tools.

The account says six days passed from the purchase order to arrival at the site, and that the operator finished the repair with no product loss and no downtime. Those statements are the vendor’s. Grade and pressure are not given.