# Advisory bulletins that bear on repair

In short. ADB-2026-02 on Type A sleeves and ADB-2016-04 on shielding coatings, and where to find the rest of the bulletin index.

Advisory bulletins are Federal Register notices. They do not amend Parts 192 or 195. They are still the place PHMSA writes down a failure pattern it wants operators to look for. Two of them sit directly on the repair and coating problems this reference covers. The index of the others is on PHMSA’s notices page; this article does not pretend to be that index.

## ADB-2026-02 — Type A sleeves

Published 28 January 2026 at 91 FR 3780. PHMSA tells hazardous-liquid operators that Type A sleeves — ends not welded to the carrier — have failed because of installation problems, water in the annulus, and assessment methods that could not see the carrier. The mechanism is the same one the industry already knows from cased crossings: electrolyte in a tight annulus, cathodic-protection current shielded by the steel shell, corrosion, and fatigue at the unwelded ends where liquid lines cycle. The bulletin cites releases under sleeves that had been installed to repair dents years earlier. It recommends records that identify every sleeve and the defect under it, use of ILI to find sleeves that have no record, an inventory that says which repairs are temporary, and threat models that combine the original dent or metal loss with fatigue and the coating. The accompanying news release states the legal limit in one sentence: the bulletin does not restrict the use of Type A sleeves.

The longer public list, including a local copy of the Federal Register PDF, is [official repair guidance](/regulations/official-guidance/). The [Type A note](/repair-methods/type-a-sleeves) carries the engineering discussion. The point here is classification. An operator who treats ADB-2026-02 as a ban is over-reading it. An operator who treats it as optional reading, with sleeves missing from the alignment sheet, is under-reading the failure mode the bulletin documents.

## ADB-2016-04 — insulated and shielding coatings

Published 21 June 2016. PHMSA wrote to gas, hazardous-liquid, and carbon dioxide operators after a failure investigation involving buried insulated pipe. The bulletin’s ask is to look at coatings that can shield cathodic protection once they disbond, at moisture under insulation, and at whether in-line inspection is actually able to see the threats on those segments, including stress corrosion cracking. It lists responses that range from recoating or replacing the pipe to shortening reassessment intervals and tightening repair criteria where shielding is suspected.

The bulletin is the regulatory cousin of the Marshall finding: a coating that looks intact from a holiday detector’s point of view can still be the reason the steel corrodes or cracks. Repair crews meet that coating at every dig. Replacing it with the same system, because it is what the specification still says, repeats the condition the bulletin describes. The coating notes on this site stay at that level and do not turn the bulletin into a ban on any named product.

Older bulletins on internal corrosion (including ADB-08-08) and on corrosion of newly built lines are on the PHMSA index. Use the index rather than a partial list when the question is “did PHMSA speak to this?” A bulletin number that does not resolve in the Federal Register is not a source.

## Sources

- [ADB-2026-02, 91 FR 3780](https://www.federalregister.gov/documents/2026/01/28/2026-01675/pipeline-safety-advisory-bulletin-on-the-integrity-risks-of-type-a-repair-sleeves) — Federal Register
- [PHMSA news release on the Type A advisory](https://www.phmsa.dot.gov/news/phmsa-safety-advisory-addresses-risks-associated-use-type-sleeves) — PHMSA
- [ADB-2016-04, corrosion from insulated coatings](https://www.federalregister.gov/documents/2016/06/21/2016-14651/pipeline-safety-ineffective-protection-detection-and-mitigation-of-corrosion-resulting-from) — Federal Register
- [PHMSA notices and advisory bulletins](https://www.phmsa.dot.gov/standards-rulemaking/notices-and-advisory-bulletins) — PHMSA