# Repair of dent-and-gouge damage by grinding and composite wraps, 2009

In short. For a D/t of 50, curve fits in the article give average lives of 1,144 cycles for unrepaired dent-and-gouge damage, 6,710 cycles after grinding only, and 221,918 cycles after grinding plus a composite wrap, at a 50 percent MAOP pressure range.

Source: Alexander, C. (Stress Engineering Services, Inc.). “Repair of Pipelines Having Mechanical Damage and Plain Dents Using Composite Materials.” Article 2 in a four-part series, *Pipeline & Gas Technology*, Hart Energy Publishing, August 2009. A public copy is posted by the Composite Repair Users Group.

## What was tested

Dent-and-gouge mechanical damage, repaired by grinding the gouge, filling the dent, and installing a composite wrap, compared with grinding alone and with unrepaired defects. The article draws on programs covering nine composite repair systems. Fatigue plots compile results from six of those systems.

## Setup

The later programs used 12.75-inch Grade X52 pipe in two walls: 0.188 inch (D/t = 68) and 0.375 inch (D/t = 34). Six-inch EDM gouges, 15 percent of wall, with a Charpy-like 90-degree bevel, were placed in the pipe. A 6-inch-wide plate then indented the pipe to 15 percent of outside diameter, offset 2 inches from each gouge, for an 8-inch defect. After elastic rebound, the pipe was held at 50 percent of MAOP (36 percent of SMYS) for five minutes and the profile was measured again. Gouges were removed with a hand grinder and checked with dye penetrant; filler was placed in the dent before the wrap was installed. The procedures section states that those samples were then cycled at 100 percent MAOP, given as 100 to 1,200 psi for the 0.188-inch wall pipe and 100 to 2,300 psi for the 0.375-inch wall pipe, until a leak, with failed defects cut out so cycling of the remaining defects could continue.

## Key numbers

Figure 7 compiles unrepaired, grind-only, and grind-plus-composite results across a range of D/t ratios. The figure caption states a pressure range of 50 percent MAOP, with 15 percent initial dent depth and 15 percent initial gouge depth. From those curve fits, the article gives these average cycles to failure for a pipe with D/t = 50 (about 12.75-inch diameter and 0.25-inch wall):

- Unrepaired dent-and-gouge damage: 1,144 cycles
- Grinding only: 6,710 cycles
- Grinding plus composite materials: 221,918 cycles

The article then divides 221,918 by a factor of 20 to get 11,096 design cycles, and, at 100 cycles per year at 50 percent MAOP, about 110 years. That conversion is the article’s arithmetic, not a code allowable.

## Takeaways

On the compiled data set, grinding alone raised the average life at D/t = 50 by about a factor of six relative to the unrepaired dent-and-gouge condition, and adding a composite wrap after grinding raised it further, to 221,918 cycles in that same comparison. The article notes scatter in the combined composite data and less scatter within a single system. The pressure range attached to Figure 7 (50 percent MAOP) is not the same as the 100 percent MAOP range stated in the procedures section for the later programs.

The article is available from the [Composite Repair Users Group](https://www.compositerepair.org/wp-content/uploads/2014/10/PGT-Aug-2009-Article-2.pdf).

## Sources

- [Repair of Pipelines Having Mechanical Damage and Plain Dents Using Composite Materials](https://www.compositerepair.org/wp-content/uploads/2014/10/PGT-Aug-2009-Article-2.pdf) — Pipeline & Gas Technology (Hart Energy), August 2009