Home Defect assessment Sleeve MAOP tables Assessment
Steel repair sleeve MAOP tables Design pressure of a steel repair sleeve from the Barlow formula, tabulated for two joint efficiencies. Source: Allan Edwards, Inc. (2026).
How a cell was made
P = 2 S t / D × F × E × T, with T = 1. D is the sleeve outside diameter: standard pipe outside diameter plus twice the sleeve wall that is actually there. A milled wall is the listed wall minus 1/16 inch. Each printed psig value is the truncation of that result, not a rounded number. F is the factor printed on the class row. Class 1 Division 1 is printed as 0.80, the ASME B31.8 split. 49 CFR 192.111 sets Class 1 at 0.72 and does not divide Class 1. Liquid lines use 49 CFR 195.106 . These cells are not a substitute for the operator’s design and MAOP records. The screening calculators are on the calculator page .
PDF, E = 1.0 PDF, E = 0.8
Loading the tables.
Class F Material Finish NPS Wall psig