07 · Case studies
Case studies
Documented repairs and repair failures, each tied to a public source or a named publisher’s field account.
- Type A sleeve
Type A sleeve leak on the Twin Oaks Pipeline, Upper Makefield Township, Pennsylvania
Jet-fuel leak in 2025 under a 1995 Type A sleeve on the Twin Oaks Pipeline, caused by water ingress and near-neutral stress-corrosion cracking.
- Type B sleeve
Type B sleeve leak on the Marysville-Toledo Crude Pipeline, Sterling Heights, Michigan (CAO 4-2026-025)
Crude oil leak in 2026 from two holes in a 2010 Type B sleeve seam weld on the 16-inch Marysville-Toledo pipeline, leading to CAO 4-2026-025.
- Type A sleeve
Type A sleeve leak on Colonial Line 1, Huntersville, North Carolina (CPF 2-2021-005-NOPSO)
2020 gasoline leak on Colonial Line 1 in Huntersville, NC, from corrosion fatigue under a 2004 Type A sleeve installed over a shallow dent.
- Type A sleeve
Type A sleeve leak on Colonial Line, Gwinnett County (Harbins Road), Georgia
2016 gasoline leak on Colonial Pipeline in Gwinnett County, GA, caused by fatigue cracks and corrosion under a 2005 Type A sleeve.
- Type A sleeve
Type A sleeve leak on the CNG/Plantation pipeline, Belton, South Carolina
2014 gasoline leak on the CNG/Plantation pipeline in Belton, SC, originating under a 1991 Type A sleeve due to dent-filler degradation.
- Compression sleeve
Type C compression-sleeve repairs on the Oasis Pipeline, Texas
Vendor account of 22 Type C compression sleeves installed in service on a 36-inch Texas gas line for SCC and DSAW seam defects.
- Type B sleeve
In-service X70 Type B sleeve installation on West-East Gas Pipeline Line 3, China
In-service installation of Grade X70 Type B steel sleeves on West-East Gas Pipeline Line 3 to match carrier-pipe strength and cut shell weight.
- Clamp
Subsea Clamp+Sleeve repair of a buckled 10-inch crude line, South Marsh Island Block 59
Custom 10-by-72-inch subsea Clamp+Sleeve engineered from a diver cast and 3D scan to reinforce a buckled Gulf of Mexico crude line.
- Clamp
ROV-installed Flange Repair Split+Sleeve on a 10-inch water-injection line, offshore Angola
ROV-installed Split+Sleeve enclosure built from subsea photogrammetry to seal a leaking 900-pound flange 80 meters deep off Angola.
- Clamp
ROV-installed leak-sealing clamp on a 10-inch water-injection riser flange, Foinaven field
Deepwater ROV-installed clamp with seabed-mixed resin injection to seal a 10-inch water-injection flange leak at 500 meters.
- Clamp
Emergency leak repair on a 30-inch onshore pipeline with a bolt-on fitting
Vendor account of a same-day emergency leak repair on a 30-inch onshore pipeline using a stocked bolt-on fitting.
- Composite wrap
Composite sleeve repair of 900 feet of cooling-tower corrosion on a U.S. refinery pipeline
Installation of 903 pre-cured composite sleeves along 900 feet of corroded 8-inch U.S. refinery piping while remaining in service.
- Composite wrap
Composite sleeve repair of a dent and seam-weld crack on a 24-inch crude-oil pipeline
Non-welded pre-cured composite reinforcement of a dent and ground-out seam-weld crack on a 24-inch X52 crude pipeline.
- Composite wrap
Underwater composite sleeve repair of girth-weld corrosion on a 12-inch gas pipeline
Submerged in-service composite sleeve repair bridging 74 percent girth-weld corrosion on a 12-inch gas pipeline at 68 bar.
- Composite wrap
Composite sleeve repair of a rockfall dent on a 36-inch hydroelectric pipeline in the French Alps
Helicopter-mobilized pre-cured composite reinforcement for cyclic fatigue on a rockfall-dented 36-inch X60 penstock in the French Alps.
- Composite wrap
Burst test of a composite sleeve repair recovered after 25 years in service (installed 1995)
Hydrostatic burst test of a pre-cured composite sleeve cut out after 25 years in gas service; pipe ruptured at 2,180 psi outside the repair.
- Composite wrap
Composite pipe-wrap repairs of corrosion on Equistar Pipeline, Texas
Woven-fiberglass epoxy composite repair of severe external corrosion under wet tape on a Texas pipeline in brine-saturated soil.
- Composite wrap
Weld-wrap composite reinforcement of an internal weld defect on a 24-inch products pipeline, Western Europe
MFL-visible composite reinforcement of an internal weld defect on a 24-inch refined-products line cured at -7 C with heating blankets.
- Composite wrap
Composite repair of a 32-inch offshore riser, Thailand
Composite and subsea-epoxy reinforcement of severe wall loss on a 32-inch offshore gas riser in Thailand, avoiding a prolonged shutdown.
- Composite wrap
Splash-zone composite repair of mechanical damage on a 12-inch subsea crude line, Gulf of Mexico
Diver-applied underwater carbon-fiber wrap with splashzone resin repairing two meters of mechanical damage on a 12-inch Gulf crude line.
- Composite wrap
Carbon-fiber repair of a deep crack on a 900 mm gas-transmission bend
Nine-ply carbon-fiber composite reinforcement of an 80 percent through-wall longitudinal crack on a 900 mm gas-transmission bend.
- Epoxy-filled shell
Epoxy-filled sleeve encapsulation of a large dent on a 14-inch trunkline, Papua New Guinea
Custom enlarged-body epoxy-filled steel sleeve encapsulating a large landslide dent on a 14-inch trunkline in Papua New Guinea.
- Hot tap / line stop
High-pressure line-plug isolation to remove a stuck pig and replace a leaking valve on a CO2 pipeline
In-service double line-plug isolation above 2,000 psi on a sour dense-phase CO2 pipeline to retrieve a stuck pig and replace a leaking valve.
- Hot tap / line stop
Line-plug train isolation and diversion of two 24-inch gas transmission lines under a planned Singapore subway station
Three simultaneous double line-plug train isolations with 24-inch bypasses to divert twin 40-bar gas lines under a Singapore subway site.
- Hot tap / line stop
Line-plug train isolation to decommission a gas-processing plant off a 36-inch transmission line, Alabama
Custom 60-bar double-block-and-bleed line stop with internal bypass on a 36-inch gas trunkline to isolate an Alabama plant for demolition.
- Hot tap / line stop
Emergency double line-plug isolation of a burning 14-inch NGL pipeline after a third-party strike, West Texas
Emergency hot tap and double line-plug isolation to extinguish and isolate a burning 14-inch NGL pipeline after a third-party strike.
- Hot tap / line stop
12-inch double line-plug isolation with bypass for a live gas-line repair, Oklahoma
Live 12-inch double line-plug line stop with full-size bypass maintaining downstream gas delivery during an Oklahoma pipeline repair.
- Hot tap / line stop
Line stop to connect 8-inch PE gas mains, St. Louis
Mechanical line stop through a hot-tap fitting on an 8-inch polyethylene gas distribution main in St. Louis without pipe squeezing.
- Hot tap / line stop
Insertion valves and line stops after a sheared 8-inch valve, Covington, Ohio
Emergency insertion valves and line stops on 4- to 12-inch municipal mains to isolate a sheared 8-inch valve without shutting down service.
- Recoating
Epoxy recoating of HDD-damaged girth and spiral welds, Kansas
Field recoating of HDD rock-scuffed girth and spiral welds in Kansas using a field-applied epoxy coating and a sacrificial abrasion wrap.
- Composite wrap
West Virginia 30-inch leak at a previous composite wrap
A leaking defect at an older composite wrap on a 30-inch gas line, sealed with a metal-repair compound and then reinforced with an E-glass wrap.
- Composite wrap
Port Allen valve-station dent reinforced with an E-glass wrap
An 8-inch above-ground line in a Louisiana valve station, dented by a vehicle, then reinforced with an E-glass composite wrap while the line stayed in service.
- Composite wrap
14-inch diesel line at Redding, Pennsylvania, carbon wrap
A 41-foot carbon-fiber wrap on a shut-in 14-inch diesel line after an in-line inspection call of lack of fusion, dents, and wrinkle bends.
- Mechanical protection
Hinged protective tools on a 24-inch Florida line during bridge work
Hinged protection tools placed on an above-ground 24-inch line while concrete bridge supports were replaced, then removed. Not a pressure-containing repair.
- Type B sleeve
Custom Type B sleeve around an existing clamp, Florida
A Type B sleeve shaped to enclose a leak-repair clamp on an 8-inch above-ground line over coastal water, where beams and a small pipe left little room.
- Type B sleeve
Type B sleeves replacing mechanical clamps at a Texas refinery
A refinery ordered steel sleeves to replace mechanical clamps that had to come off at every shutdown. The operator is not named.
- Type A sleeve
Double-hump girth-weld sleeve on a 26-inch Kentucky gas line
A custom 40.5-inch sleeve covering corrosion next to two closely spaced girth welds, where a standard half-sole would not fit.
- Compression sleeve
Compression sleeve on a crude line, Middle East operator
A shop trial and a first live compression-sleeve install, taken from a forthcoming conference paper. The operator is not named because the paper is not in the public proceedings.