06 · Coatings and corrosion protection
Coatings and corrosion protection
Plant coatings, field joints, surface preparation, and cathodic protection as they affect repair.
Coating types
FBE, three-layer polyethylene, coal-tar enamel, tape, and liquid epoxies, described by what they do on a buried line and how they fail.
Cathodic protection basics
What the federal criteria actually are, how shielding defeats them, and what a repair crew changes when it exposes the pipe.
Surface preparation
The cleanliness grades field coatings and composite repairs actually depend on, named but not copied from the copyrighted visual standards.
Field joint coatings
The plant coat stops at the weld. What gets applied in the field, and why that strip dominates coating failures.
Coating at repair sites and post-repair coating surveys
The coating obligations that follow a repair: coat and protect replaced or repaired pipe, inspect before backfill, and, on gas transmission, a DCVG or ACVG survey within 6 months when 1,000 feet or more is backfilled, with severe damage repaired on a set clock.
Cased crossings and shielded corrosion
Why a steel casing under a road or railroad is a corrosion and assessment problem: isolation requirements in §192.467 and §195.575, casing design in §192.323, metallic and electrolytic contacts, PHMSA's cased-pipe ECDA guidelines, and repairs made inside or at the end of a casing.