00 · New to pipelines

How pipelines work

In short Gas and liquid lines, gathering, transmission and distribution, and what pressure, stress, MAOP and SMYS mean in plain English.

Updated . Sources are listed at the end. Markdown version.

A pipeline is a long run of steel pipe, welded together, carrying a fluid from where it is produced to where it is used. Most of it is buried. Pumps or compressors push the product along, valves split the line into sections, and the pipe wall holds the pressure in. Everything else on this site, from defects to repairs, comes back to one question: can the wall still hold that pressure?

Gas lines and liquid lines

Gas pipelines carry natural gas and other flammable, toxic or corrosive gases. Gas is compressed, so a gas line stores a lot of energy. A failure releases that energy quickly. Hazardous liquid pipelines carry crude oil, refined fuels, other petroleum products, anhydrous ammonia, ethanol and similar products. The U.S. liquid rules in 49 CFR 195.2 define the term that way. A liquid line stores less energy for the same pressure, but a release can travel along the ground, into water, or through drainage before anyone reaches it.

The two kinds of line are regulated under different parts of the federal rules (Part 192 for gas, Part 195 for hazardous liquids), and the repair rules differ in detail. The Regulations section covers both.

Gathering, transmission and distribution

Gas systems are usually described in three stages.

  • Gathering lines collect product from production facilities and bring it toward a processing plant or a larger line. In the U.S. gas rules a gathering line is one that carries gas from a current production facility to a transmission line or main.
  • Transmission lines are the large, long-distance lines. Under the U.S. gas definition in 49 CFR 192.3, a transmission line moves gas from a gathering line or storage facility to a distribution center, storage facility or large-volume customer. It also includes a line that operates at a stress of 20 percent or more of SMYS, and lines inside storage fields.
  • Distribution lines are the smaller lines and service lines that deliver gas to homes and businesses. The gas rules define a distribution line by exclusion: it is a pipeline that is neither a gathering line nor a transmission line.

Liquid systems follow a similar pattern, with gathering lines near the field, long trunk lines between facilities, and breakout tanks and terminals along the way. In the U.S. liquid rules a gathering line is a petroleum line of 8⅝ inches nominal outside diameter or less that carries product from a production facility.

The category matters because it decides which rules apply and how often a line is inspected. A repair that is routine on a distribution main may be a regulated event on a transmission line.

Pressure, stress and wall thickness

Pressure inside a pipe pushes the wall outward. The wall resists by carrying tension around its circumference. That tension, spread over the wall thickness, is the hoop stress. The simple relationship is called the Barlow formula: hoop stress rises with pressure and diameter, and falls as the wall gets thicker. Double the diameter at the same pressure and wall, and the stress doubles. Double the wall, and the stress halves. The calculators on this site run the formula, and the glossary defines it.

Pipe steel is graded by how much stress it can take before it starts to deform permanently. That value is the yield strength. The specified minimum yield strength (SMYS) is the minimum value written into the pipe specification the pipe was made to. If the specification is unknown, the U.S. gas rules provide a way to determine a value instead.

Engineers describe how hard a pipe is working as a percentage of SMYS. A line operating at a low percentage has a large margin. A line at a higher percentage has less. That is why the 20 percent of SMYS figure shows up in the definitions above, and why pipe near people is usually designed with a bigger margin.

MAOP and MOP

The maximum allowable operating pressure (MAOP) is the highest pressure at which a gas pipeline segment may be operated under the rules. Section 192.3 defines it in one line. The liquid-line equivalent is the maximum operating pressure (MOP), the highest pressure at which a segment may be normally operated.

MAOP is not the same as the pressure the line runs at on a given day. Operators normally run below it. MAOP is also not the pressure the pipe was tested to. A pressure test goes above MAOP so that the test shows the pipe has a margin. MAOP is set from the design, the test, the pipe, and the location, and it can be lowered after a defect is found.

That last point matters for repair. Reducing pressure is often the first step after a defect is found, and the MAOP of a repaired section depends on what the repair can carry. See selecting a repair.

Location matters

The U.S. gas rules sort the land along a line into class locations based on how many buildings are nearby, and they set more conservative design margins where more people live. Some segments are also designated as high consequence areas or moderate consequence areas, where an incident could do the most harm. Those segments get additional inspection and repair requirements. The glossary has short definitions of each term.

Where to go next

— The Pipeline Repairs team

Sources

  1. 49 CFR 192.3 — Definitions (gas pipelines) — eCFR
  2. 49 CFR 195.2 — Definitions (hazardous liquid pipelines) — eCFR
  3. Landowner's Guide to Pipelines (2011) — Pipeline Safety Trust, hosted by PHMSA
  4. Natural gas pipelines — U.S. Energy Information Administration

Also in New to pipelines

Spotted an error? Engineers keep this site honest.Report an error or suggest a correction

Open the form on this page

Occasional updates