07a · Worked examples
Example: choosing between a reinforcement and a cut-out
In short An invented dent-and-gouge decision, labeled as an example, showing the questions a real note would have to answer from the regulations.
Assumed feature
Assume a top-side dent on a gas transmission line, reported at about 3 percent of the diameter, with a longitudinal gouge in the dent. No company. No milepost. The combination — upper two-thirds of the pipe, plus a stress concentrator — is the pattern §192.714 and §192.933 treat as immediate unless an engineering analysis under §192.712(c) shows critical strain is not exceeded. A real note would paste the clause that applies to that segment’s HCA status rather than gesture at both sections.
The decision the example refuses to fake
A cut-out removes the dent and the gouge and leaves two girth welds and a known pup, as the cut-out note describes. A reinforcement is available only after the gouge is ground out and shown to be free of cracks, which is the order in the TTO-10 report and in the gouge note. A Type A sleeve installed over the gouge without that step is the repair ADB-2026-02’s failure stories keep returning to, even though the bulletin is addressed to liquid operators.
This example does not pick a winner. Picking a winner would require a strain analysis, a fatigue spectrum, material records, and a procedure. Inventing those would look like a case study and would be a fabrication. The template ends at the list of missing inputs:
- Measured dent profile, not a single depth.
- Confirmation the gouge was or was not cracked, by a named nondestructive method.
- Whether the dent is restrained.
- Pressure-cycle severity, which is why a gas line and a liquid line do not share a reflex answer. The PRCI installation-pressure abstract cited from the dent note is the kind of public research a real discussion would attach, with the pipe size left attached to the result.
- The record that will exist in twenty years: defect, method, filler or weld, coating, and whether anyone called the repair temporary.
When a later editor replaces this file, the example banner comes off only if every number is sourced. Otherwise the banner stays.
Sources
Related notes
- Screening calculators (Barlow, §192.105, B31G) — Assessment
- Corrosion metal loss — Defect assessment
- Dents — Defect assessment
- Choosing a repair — Repair methods