06 · Coatings and corrosion protection
Cathodic protection basics
In short What the federal criteria actually are, how shielding defeats them, and what a repair crew changes when it exposes the pipe.
Cathodic protection drives the steel’s potential in the soil negative enough that the dissolution reaction slows to something the design can live with. It is direct current, from sacrificial anodes or from a rectifier and a groundbed. It protects bare steel that the current can reach. It does not protect steel behind a disbonded shield, and it does not replace a coating.
Section 192.455 requires buried or submerged steel transmission lines and some other facilities to have an external protective coating and a cathodic-protection system, with stated exceptions that have to be read rather than remembered. Section 192.463 requires the system to meet the criteria in Appendix D of Part 192, or another criterion the operator can show provides comparable protection. Section 195.571 points liquid operators at the same appendix. Appendix D is public regulatory text. It includes a negative polarized potential of at least 0.85 volt relative to a saturated copper/copper-sulfate electrode, and a 100-millivolt polarization criterion, among others. The appendix requires that voltage drops other than the drop across the structure-to-electrolyte boundary be considered for the polarized criteria. That is why an “on” potential, taken while the rectifier is running, is not automatically a passing reading: the soil IR drop is in the number. Instant-off measurements are the field technique used to reduce that error. Read the appendix for the criterion you are applying. This paragraph is a map, not a copy.
AMPP/NACE SP0169 is the consensus standard on control of external corrosion of buried or submerged metallic piping. Many procedures incorporate it. Whether a given edition is incorporated into federal law is a question for §192.7 and §195.3, not for this page. The regulatory criteria remain Appendix D.
What a repair does to the system
Excavation breaks coating, possibly bonds a sleeve into the electrical circuit, and can shield a rectangle of pipe if the repair is a Type A sleeve or a disbonded patch. ADB-2026-02 compares a wet sleeve annulus to a shorted casing. ADB-2016-04 and the Marshall report describe coatings that pass enough of a holiday test to look managed while hiding the steel from current. After a dig, the coating has to be reinstated with a system that does not shield, the holiday test has to include the repair, and someone who understands the rectifier and the test stations has to know the pipe was exposed. A repair report that ends at “sleeve installed” is electrically incomplete.
Stray current, interference from neighboring lines, and shielding at casings are the subjects of §§192.465, 192.467, and 192.473 and the liquid parallels. They are not solved from a ditch. They are the reason a coating repair on a line with a known interference problem gets a corrosion technician, not only a coating kit.
Internal corrosion is a different mechanism — water and contaminants in the product, not a missing rectifier. Grinding an external pit does nothing for an internal one, and an external wrap does not stop it. The 2025 court correction removed §192.478, the internal-corrosive-constituent monitoring section added in 2022. Other internal-corrosion duties in Part 192 did not disappear with it. Read Subpart I as it stands.
Sources
- 49 CFR 192.455 — External corrosion control, buried or submerged — eCFR
- 49 CFR 192.463 — External corrosion control, cathodic protection — eCFR
- 49 CFR Part 192 Appendix D — eCFR
- 49 CFR 195.571 — eCFR
- ADB-2016-04 — Federal Register
- NTSB/PAR-12/01 — NTSB
- AMPP home, publisher of SP0169 — AMPP
Related notes
- Type A steel sleeves — Repair methods
- Advisory bulletins that bear on repair — Regulations and official guidance
- Corrosion metal loss — Defect assessment
- Type A sleeve leak on the Twin Oaks Pipeline, Upper Makefield Township, Pennsylvania — Case studies
Also in Coatings and corrosion protection
Spotted an error? Engineers keep this site honest.Report an error or suggest a correction