06 · Coatings and corrosion protection

Coating types

In short FBE, three-layer polyethylene, coal-tar enamel, tape, and liquid epoxies, described by what they do on a buried line and how they fail.

Updated . Sources are listed at the end. Markdown version.

The coating is the primary corrosion barrier on a buried steel pipeline. Cathodic protection is the second system, for the holidays and the damage. A repair that restores the steel and then leaves the wrong coating, or no coating, has traded a known defect for a new corrosion cell. Part 192 Subpart I and Part 195 Subpart H require external coating on buried or submerged steel, compatible with cathodic protection. They do not name a brand.

Fusion-bonded epoxy (FBE) is a plant-applied powder, melted onto a blasted and heated pipe. It is a thin thermoset film. It is also the primer under three-layer systems. Standalone FBE does not shield cathodic protection the way a disbonded polyolefin film can: if it holidays, current can reach the steel. It does not survive a careless backfill, and it needs a field joint coating at every girth weld because the plant coat stops short of the bevel. CSA Z245.20 is the plant-FBE specification widely specified in North America. It is a standards-body document, not a federal rule.

Three-layer polyethylene (3LPE) adds a copolymer adhesive and a polyethylene topcoat over an FBE primer. The polyethylene is the handling and rock shield. It is also, if it disbonds and water enters, a shield. Three-layer polypropylene is the higher-temperature version of the same idea. ISO 21809-1 is the international plant-coating standard this family is bought against. The repair question is local: at a dig, do you recoat with a system that matches the plant coat’s service temperature and that does not recreate a shielding flap over the weld.

Coal-tar enamel is the historical transmission coating, often with a felt wrap. A great deal of it is still in the ground and still performing. It also cracks, and it is unpleasant and regulated as a material to remove. Recoating a coal-tar cutback with a modern epoxy requires removing the enamel back to a clean edge. Painting epoxy over intact enamel because the enamel “looks fine” is how the new coat lets go at the first holiday.

Tape, particularly polyethylene backed tape, is the system the Marshall report tied to disbondment, shielded cathodic protection, and the corrosion-fatigue colony that ruptured Line 6B. Tape is still encountered on older lines and, less defensibly, in a ditch as a quick recoat. ADB-2016-04 generalized the shielding problem to buried insulated coatings. The practical instruction from those two public documents is the same. If the coating can hide wet steel from the cathodic-protection current, the integrity plan has to assume corrosion or stress corrosion cracking under it, and the repair should not put that coating back.

Liquid epoxies are the field coatings: two-part materials brushed or sprayed on a prepared weld or a grind. They are only as good as the surface, the mix ratio, the temperature, and the cure before backfill. They are the usual choice for a recoat of modest area and for many field joints. A liquid epoxy specified for atmospheric service is not a buried-pipeline coating. The data sheet’s buried, cathodic-protection-compatible, temperature-rated product is the one the procedure should name.

This note does not rank brands. The specification that belongs in the repair record is the product, the surface-preparation grade that was achieved, the batch, the conditions, and the holiday test. The field joint note and the surface preparation note are the other two halves of that record.

Sources

  1. NTSB/PAR-12/01, disbonded polyethylene tape — NTSB
  2. ADB-2016-04, shielding and insulated coatings — Federal Register
  3. 49 CFR 192 Subpart I, corrosion control — eCFR
  4. 49 CFR 195 Subpart H, corrosion control — eCFR
  5. AMPP, publisher of coating and corrosion standards — AMPP

Also in Coatings and corrosion protection

Spotted an error? Engineers keep this site honest.Report an error or suggest a correction

Open the form on this page

Occasional updates