Burst test of a 24-inch leaking pipe with a Type B sleeve, 2019

In short A Type B sleeve on a 24-inch X65 pipe with through-holes failed at 2,578 psig, about 126 percent of SMYS.

Updated . Sources are listed at the end. Markdown version.

Source: Allan Edwards, Inc.; testing by ADV Integrity, Inc. (2019). Report 100101-RP01-Rev2-042219, April 2019.

What was tested

A Type B steel sleeve supplied by Allan Edwards was welded onto a 10-foot length of 24-inch outside diameter, 0.375-inch wall, Grade X65 pipe. Nine 1/2-inch through-holes were drilled under the sleeve so the repair, not the bare pipe, held the pressure.

Setup

The burst procedure held the sample near 72 percent of specified minimum yield strength and near 100 percent, then took it to failure.

Key numbers

The repaired sample failed at 2,578 psig, about 126 percent of SMYS. The sleeve reached its proportional limit near 2,300 psig. The carrier pipe’s measured yield was 84.2 ksi, which corresponds to a predicted yield pressure of about 2,631 psig.

Takeaways

On this one sample the sleeve contained the leak through the holds and failed near the pipe’s actual yield, not at a low leak pressure. One specimen does not set a design pressure.

Download the report.