Full-scale testing of a compression sleeve, 2022

In short Three of four induction-installed compression sleeves reached 100,000 cycles and then burst in bare pipe outside the sleeve. One repaired sample failed at 8,858 cycles.

Updated . Sources are listed at the end. Markdown version.

Source: Allan Edwards, Inc.; testing by ADV Integrity, Inc. (2022). Report 100301-RP01-Rev2-040622, April 2022 (Rev 2). David Futch, PE, Atul Ganpatye, PE, and Dr. Chris Alexander, PE. The program began in 2019.

What was tested

Four Allan Edwards compression sleeves installed with induction heating over electro-discharge-machined notches.

Setup

Pipe was 12.75-inch outside diameter by 0.188-inch wall. Clamps were actuated to 4,000 psi, which is the pressure in the Allan Edwards procedure. Cycling ran from 150 to 1,104 psig, about 10 to 72 percent of SMYS.

Key numbers

Sample 1 developed a through-wall path at 8,858 cycles. Samples 2, 3, and 4 reached the 100,000-cycle runout and were then burst. All three failed in the base pipe outside the sleeve, at 2,188, 2,200, and 2,195 psi, about 143 percent of SMYS. An unreinforced 50 percent notch from earlier related work failed at 896 cycles.

Takeaways

Three runouts and bursts outside the sleeve are in the same report as the sample that leaked at 8,858 cycles. The early failure is part of the result. The runouts are not a code allowable.

Download the report.