Backing-strip mill groove on a Type B sleeve, 2021
In short Two 12-inch Type B sleeves, one with a long-seam mill groove and one without, both reached 100,000 pressure cycles without a sleeve failure.
Source: Allan Edwards, Inc.; testing by ADV Integrity, Inc. (2021). Report 100306-RP03-Rev0-110221, November 2021. Mark Holland, David Futch, PE, and Dr. Chris Alexander, PE.
What was tested
Whether a mill groove that lets a long-seam backing strip sit against the pipe changes the cyclic life of a Type B sleeve. Two 12-inch sleeves, one grooved and one not, reinforced dents.
Setup
Pressure cycled from 132 psig (8 percent of SMYS) to 1,318 psig (80 percent of SMYS), toward a 100,000-cycle runout.
Key numbers
Both samples reached 100,000 cycles without a sleeve failure. The grooved sample leaked at a pressure port in the end cap at 92,416 cycles. That port was repaired and cycling continued to runout with no further leak.
Takeaways
The leak was isolated to the end-cap port, not the sleeve. On this program the mill groove did not produce a sleeve failure inside 100,000 cycles.
Sources
- Backing-strip mill groove on a Type B sleeve, 2021 — Allan Edwards / ADV Integrity
Related notes
- Type B steel sleeves — Repair methods
- In-service welding and hydrogen pipelines — Repair methods
- Test reports and downloads — Test reports
- Steel compression sleeves — Repair methods
- Dents — Defect assessment
- Steel repair sleeve MAOP tables — Assessment
Also in Test reports
- Burst test of a 24-inch leaking pipe with a Type B sleeve, 2019
- Type B sleeve fit-up, tight and loose, 2021
- Full-scale testing of a compression sleeve, 2022
- Manual pipe-jack torque test, 2019
- Steel sleeves reinforcing corrosion and plain dents, 2021
- Composite repairs of corroded riser pipe under pressure, tension, and bending, 2007
- Repair of dent-and-gouge damage by grinding and composite wraps, 2009
- Fatigue testing of composite repairs on dented pipe, 2010
- Fatigue and burst testing of composite and steel-sleeve repairs on corrosion and dents, 2014
- Long-term subsea exposure testing of composite repairs, 2017
Spotted an error? Engineers keep this site honest.Report an error or suggest a correction