07 · Case studies
Type C compression-sleeve repairs on the Oasis Pipeline, Texas
In short Vendor account of 22 Type C compression sleeves installed in service on a 36-inch Texas gas line for SCC and DSAW seam defects.
Source: T.D. Williamson (2025). Account type: Vendor account.
TDW’s case study describes SCC and DSAW defects at 13 locations on a 36-inch Texas pipeline running at about 820 psig. The company installed 22 PETROSLEEVE Type C compression sleeves (36-inch by 1-inch A516-70 shells, 36 inches long) in four days, using three crews, while the line remained in service. TDW contrasts that schedule with a conventional Type B sleeve campaign that it says could have taken up to five weeks. The account is vendor marketing, but it is a concrete, recent public example of compression-sleeve use on cracking and seam-weld defects.
Method
TDW PETROSLEEVE Type C (compression) steel sleeves. Two half-shells are compressed onto the carrier pipe over epoxy; sidebars are welded to the sleeve, not to the carrier pipe.
Defect
Stress-corrosion cracking (SCC) and double-submerged-arc-weld (DSAW) defects at 13 sites
Pipe
36-inch pipeline operating at about 820 psig, Texas (Oasis Pipeline / Southeast Texas system feeding the Houston market, per TDW). Sleeves: NPS 36 x 1-inch thick x 36-inch long, ASTM A516-70.
Outcome
TDW reports 22 sleeves installed in four days with three welding crews, and says this was about a 90 percent time reduction versus a Type B sleeve campaign that might have taken up to five weeks. The line stayed in service. No safety incidents were reported by the vendor. These time and safety claims are the manufacturer’s.
Schedule, cost, and service-life figures in this note are the publisher’s claims. They were not checked against an operator record or a laboratory report.
Dates: Official case-study page does not state the installation year. TDW posted the case on LinkedIn on 21 November 2025.
Maker named in the source: T.D. Williamson (PETROSLEEVE).
Sources
- PETROSLEEVE Type C compression-sleeve repairs on the Oasis Pipeline, Texas — T.D. Williamson
- Related public record — T.D. Williamson
Related notes
- Steel compression sleeves — Repair methods
- Compression sleeves: questions engineers ask — Repair methods
- Full-scale testing of a compression sleeve, 2022 — Test reports
- ASME PCC-2 — Codes and standards
- Part 192 repair and integrity duties — Regulations and official guidance
- Choosing a repair — Repair methods
Also in Case studies
- Type A sleeve leak on the Twin Oaks Pipeline, Upper Makefield Township, Pennsylvania
- Type B sleeve leak on the Marysville-Toledo Crude Pipeline, Sterling Heights, Michigan (CAO 4-2026-025)
- Type A sleeve leak on Colonial Line 1, Huntersville, North Carolina (CPF 2-2021-005-NOPSO)
- Type A sleeve leak on Colonial Line, Gwinnett County (Harbins Road), Georgia
- Type A sleeve leak on the CNG/Plantation pipeline, Belton, South Carolina
- In-service X70 Type B sleeve installation on West-East Gas Pipeline Line 3, China
- Subsea Clamp+Sleeve repair of a buckled 10-inch crude line, South Marsh Island Block 59
- ROV-installed Flange Repair Split+Sleeve on a 10-inch water-injection line, offshore Angola
- ROV-installed leak-sealing clamp on a 10-inch water-injection riser flange, Foinaven field
- Emergency leak repair on a 30-inch onshore pipeline with a bolt-on fitting
- Composite sleeve repair of 900 feet of cooling-tower corrosion on a U.S. refinery pipeline
- Composite sleeve repair of a dent and seam-weld crack on a 24-inch crude-oil pipeline
- Underwater composite sleeve repair of girth-weld corrosion on a 12-inch gas pipeline
- Composite sleeve repair of a rockfall dent on a 36-inch hydroelectric pipeline in the French Alps
- Burst test of a composite sleeve repair recovered after 25 years in service (installed 1995)
- Composite pipe-wrap repairs of corrosion on Equistar Pipeline, Texas
- Weld-wrap composite reinforcement of an internal weld defect on a 24-inch products pipeline, Western Europe
- Composite repair of a 32-inch offshore riser, Thailand
- Splash-zone composite repair of mechanical damage on a 12-inch subsea crude line, Gulf of Mexico
- Carbon-fiber repair of a deep crack on a 900 mm gas-transmission bend
- Epoxy-filled sleeve encapsulation of a large dent on a 14-inch trunkline, Papua New Guinea
- High-pressure line-plug isolation to remove a stuck pig and replace a leaking valve on a CO2 pipeline
- Line-plug train isolation and diversion of two 24-inch gas transmission lines under a planned Singapore subway station
- Line-plug train isolation to decommission a gas-processing plant off a 36-inch transmission line, Alabama
- Emergency double line-plug isolation of a burning 14-inch NGL pipeline after a third-party strike, West Texas
- 12-inch double line-plug isolation with bypass for a live gas-line repair, Oklahoma
- Line stop to connect 8-inch PE gas mains, St. Louis
- Insertion valves and line stops after a sheared 8-inch valve, Covington, Ohio
- Epoxy recoating of HDD-damaged girth and spiral welds, Kansas
- West Virginia 30-inch leak at a previous composite wrap
- Port Allen valve-station dent reinforced with an E-glass wrap
- 14-inch diesel line at Redding, Pennsylvania, carbon wrap
- Hinged protective tools on a 24-inch Florida line during bridge work
- Custom Type B sleeve around an existing clamp, Florida
- Type B sleeves replacing mechanical clamps at a Texas refinery
- Double-hump girth-weld sleeve on a 26-inch Kentucky gas line
- Compression sleeve on a crude line, Middle East operator
Spotted an error? Engineers keep this site honest.Report an error or suggest a correction