03 · Regulations and official guidance
CER safety and information advisories that bear on repair
In short The Canada Energy Regulator's advisories on dent evaluation, girth-weld strain failures, nonconforming components, and new CSA standard editions, summarized with their dates and what each asks of operators.
The Canada Energy Regulator issues two kinds of advisory to the companies it regulates. A safety advisory tells industry about an identified safety or environmental concern, highlights CER requirements, and conveys the CER’s expectation that companies take action to prevent related incidents. An information advisory passes on information, such as a new edition of a standard or the findings of audits. Neither adds a section to the Onshore Pipeline Regulations. They are the regulator’s statement of what it expects under them, and the CER asks that each be circulated to company staff and contractors. The index lists them all, and the ones that bear on repair are summarized here.
SA 2025-01: Evaluation of Dents in Pipe (19 June 2025)
The advisory raises two issues. The CER posted a correction notice on 8 July 2025.
Issue 1, API RP 1183. The CER says the fatigue-life screening in Table 6 of the first edition of API RP 1183, Assessment and Management of Pipeline Dents, may give overestimated values and can underestimate dent severity, so injurious dents could be classed as non-injurious. The advisory notes that API removed Table 6 in Addendum 1 in May 2024 and issued an updated addendum in 2025 giving the rationale, and that review of the section 7.4 screening methods is continuing. The CER expects companies to review and reassess dents previously cleared using Table 6, using other industry-recognized screening or assessment methods, to stay informed of research, and to use caution with RP 1183’s methods while they are re-evaluated.
Issue 2, construction versus operation. CSA Z662 applies different dent acceptance criteria before and after a pipeline enters service. Clause 6 governs construction and, according to the CER, is less conservative than Clause 10, which governs the operating pipeline and treats dents susceptible to pressure-cycle fatigue failure as defects unless an engineering assessment shows them acceptable. The advisory points out that a dent accepted during manufacturing or construction may not be recorded, so the integrity team may never learn of it. The CER expects companies to align their dent procedures for manufacturing and construction with the Clause 10 criteria, and recommends a system that records each acceptance decision and the dent’s location so it can be reassessed later.
For the engineering side of dent assessment, see dents and engineering critical assessment of dents.
SA 2020-01: Girth weld area strain-induced failures (12 February 2020)
The CER reported awareness of several incidents outside Canada in which girth weld areas on high-strength pipe failed by ductile fracture under longitudinal strain that exceeded the strain capacity of the weld area, even though applied global strain was of the order of 0.4 to 0.6 percent. The advisory says no such incident had been reported in Canada and that the CER believed similar incidents could occur under comparable conditions. It lists contributing factors seen in the incidents: pipe with actual tensile strength above the specified minimum, softening of the heat-affected zone, loads that impose longitudinal strain such as slope movement or subsidence, standard-bevel welds, and under-matched weld metal. It notes that weld procedures meeting API 1104 and Clause 7 of CSA Z662-19 can still be susceptible, because neither requires testing for weld strength under-match.
The CER expects companies to show that longitudinal strains, including those described in Clause 4.2.4 of CSA Z662-19, have been accounted for in design, construction, and operation where strain could accumulate in an under-matched girth weld area, and suggests reviewing welding procedure specifications and qualification records against the actual pipe properties. The advisory is relevant wherever new girth welds are made, including cut-out replacement. See cut-out and replacement.
SA 2024-01: Pipeline fitting materials quality assurance (3 December 2024)
The CER reports instances of components that failed to meet required standards even though manufacturers’ documents indicated compliance, including material toughness problems traced to sub-suppliers, materials whose origin differed from their markings, and material test reports that did not represent the material supplied. It says no failures on in-service CER-regulated pipelines had resulted. The advisory requires regulated companies to maintain quality assurance programs in line with section 15 of the OPR, to test products they suspect have not been through a robust quality assurance process, and to follow the reporting duty under Order MO-003-2018, which means notifying the CER within 15 days of finding non-compliant pipe or components. It asks companies to consider CSA EXP13-21, Quality assurance requirements for pipe and components. Repair fittings, sleeves, and replacement pipe are components, so these expectations apply to repair materials.
Information advisories on CSA standards
- IA 2023-001 (6 July 2023). The CER notes that CSA Z662:23 is incorporated by reference through section 4 of the OPR and took effect on its publication date, 30 June 2023, and expects companies to review it and ensure compliance as soon as possible. It also expects compliance with Order MO-015-2023 for the new safety-class method. See CSA Z662.
- IA 2025-001 (20 October 2025). New editions of CSA Z245.11 (steel fittings), Z245.12 (steel flanges), and Z245.15 (steel valves) were published. The CER says companies can keep using the editions referenced in Z662:23 until Z662’s next planned update in 2027, and encourages proactive use of the newer editions, particularly where the older ones do not fully address a circumstance.
Reading advisories
Each advisory carries a date and a file reference. Use the dated advisory, not a summary of it, when citing. A safety advisory states the CER’s expectation. It is not a new regulation. For the comparable U.S. documents and how much weight each carries, see advisory bulletins and official repair guidance.
Sources
- Safety and Information Advisories (index) — Canada Energy Regulator
- Safety Advisory SA 2025-01, Evaluation of Dents in Pipe (19 June 2025) — Canada Energy Regulator
- Safety Advisory SA 2020-01, Girth Weld Area Strain-Induced Failures (12 February 2020) — Canada Energy Regulator
- Safety Advisory SA 2024-01, Pipeline Fitting Materials Quality Assurance (3 December 2024) — Canada Energy Regulator
- Information Advisory IA 2023-001, CSA Z662:23 Standard (6 July 2023) — Canada Energy Regulator
- Information Advisory CER IA 2025-001, CSA Z245 Standards (20 October 2025) — Canada Energy Regulator
Related notes
- CSA Z662: Canada's oil and gas pipeline systems standard — Codes and standards
- Dents — Defect assessment
- Cut-out and replacement — Repair methods
- Dent engineering critical assessment — Defect assessment
- Choosing a repair — Repair methods
- How codes and regulations differ — Codes and standards
Also in Regulations and official guidance
- How to read PHMSA sources
- Part 192 repair and integrity duties
- Part 195 repair and integrity duties
- Gas transmission rule updates
- Official repair guidance
- Advisory bulletins that bear on repair
- Interpretations and FAQs
- PHMSA research on repair methods
- Lessons from public investigations
- Repair records for sleeves and other repairs
- Temporary and permanent repairs
- AB-539: engineered composite alterations in Alberta
- Repair schedules: gas transmission versus hazardous liquid
- Pipeline regulation in Canada: who regulates what
- CER Onshore Pipeline Regulations and pipeline repair
- Alberta: Pipeline Act, Pipeline Rules, and AER Directive 077
- British Columbia: Pipeline Regulation and BC Energy Regulator requirements
- Saskatchewan and Ontario: provincial pipeline requirements
- TSB pipeline investigation reports: what Canada's safety board publishes
Spotted an error? Engineers keep this site honest.Report an error or suggest a correction