07 · Case studies
Composite pipe-wrap repairs of corrosion on Equistar Pipeline, Texas
In short Woven-fiberglass epoxy composite repair of severe external corrosion under wet tape on a Texas pipeline in brine-saturated soil.
Source: Pipeline & Gas Journal (February 2001), quoting Equistar Pipeline corrosion engineers; archived at The Free Library (2001). Account type: Trade press.
Around 1999, Equistar Pipeline stripped wet cold-applied tape from pipe sitting in brine at Mont Belvieu, Texas, and found up to 100 mils of corrosion, with half-inch wall down to a quarter-inch in places. Engineers wrapped the pipe with Armor Plate, a woven-fiberglass epoxy composite, and the company’s corrosion engineer told Pipeline & Gas Journal that the line was returned to its original pressure rating without being depressurized. The same article describes a later 40-percent wall-loss repair under a highway right-of-way in southeast Houston and a wet barrier-coating use in a creek. The piece is promotional in tone, but it records a named operator describing field use of a non-Clock-Spring composite system.
Method
Armor Plate Pipe Wrap: woven fiberglass cloth saturated with epoxy, wrapped in multiple layers, cured ambient or with a heat blanket
Defect
At Mont Belvieu, up to 100 mils of circumferential corrosion under moisture-soaked tape in brine, with half-inch wall reduced to a quarter-inch in places. At a southeast Houston highway right-of-way, pitting with about 40 percent wall loss. A third site used the wrap as a barrier coating on pipe under an active creek.
Pipe
Equistar Pipeline sites at Mont Belvieu and Alvin / southeast Houston, Texas. Nominal diameter and grade are not stated. The Mont Belvieu pipe is described as originally half-inch wall.
Outcome
Equistar’s senior corrosion engineer is quoted as saying Armor Plate restored the pipe to its original pressure rating and was used as a permanent repair, applied without depressurizing the line. These are contemporaneous operator comments in a trade magazine, not a laboratory report.
This account is taken from a public regulatory or investigative record.
Dates: Article dated 1 February 2001, describing work from about 1999-2000.
Maker named in the source: Armor Plate (Wil-Cor).
Sources
- Cynthia Greenwood, Composite Pipe Repair Method Shows Versatility, Long-Lasting, Pipeline & Gas Journal, February 2001 — Pipeline & Gas Journal, quoting Equistar Pipeline corrosion engineers
Related notes
- Composite wraps — Repair methods
- ASME PCC-2 — Codes and standards
- ISO 24817 — Codes and standards
- Corrosion metal loss — Defect assessment
- AB-539: engineered composite alterations in Alberta — Regulations and official guidance
- Choosing a repair — Repair methods
Also in Case studies
- Type A sleeve leak on the Twin Oaks Pipeline, Upper Makefield Township, Pennsylvania
- Type B sleeve leak on the Marysville-Toledo Crude Pipeline, Sterling Heights, Michigan (CAO 4-2026-025)
- Type A sleeve leak on Colonial Line 1, Huntersville, North Carolina (CPF 2-2021-005-NOPSO)
- Type A sleeve leak on Colonial Line, Gwinnett County (Harbins Road), Georgia
- Type A sleeve leak on the CNG/Plantation pipeline, Belton, South Carolina
- Type C compression-sleeve repairs on the Oasis Pipeline, Texas
- In-service X70 Type B sleeve installation on West-East Gas Pipeline Line 3, China
- Subsea Clamp+Sleeve repair of a buckled 10-inch crude line, South Marsh Island Block 59
- ROV-installed Flange Repair Split+Sleeve on a 10-inch water-injection line, offshore Angola
- ROV-installed leak-sealing clamp on a 10-inch water-injection riser flange, Foinaven field
- Emergency leak repair on a 30-inch onshore pipeline with a bolt-on fitting
- Composite sleeve repair of 900 feet of cooling-tower corrosion on a U.S. refinery pipeline
- Composite sleeve repair of a dent and seam-weld crack on a 24-inch crude-oil pipeline
- Underwater composite sleeve repair of girth-weld corrosion on a 12-inch gas pipeline
- Composite sleeve repair of a rockfall dent on a 36-inch hydroelectric pipeline in the French Alps
- Burst test of a composite sleeve repair recovered after 25 years in service (installed 1995)
- Weld-wrap composite reinforcement of an internal weld defect on a 24-inch products pipeline, Western Europe
- Composite repair of a 32-inch offshore riser, Thailand
- Splash-zone composite repair of mechanical damage on a 12-inch subsea crude line, Gulf of Mexico
- Carbon-fiber repair of a deep crack on a 900 mm gas-transmission bend
- Epoxy-filled sleeve encapsulation of a large dent on a 14-inch trunkline, Papua New Guinea
- High-pressure line-plug isolation to remove a stuck pig and replace a leaking valve on a CO2 pipeline
- Line-plug train isolation and diversion of two 24-inch gas transmission lines under a planned Singapore subway station
- Line-plug train isolation to decommission a gas-processing plant off a 36-inch transmission line, Alabama
- Emergency double line-plug isolation of a burning 14-inch NGL pipeline after a third-party strike, West Texas
- 12-inch double line-plug isolation with bypass for a live gas-line repair, Oklahoma
- Line stop to connect 8-inch PE gas mains, St. Louis
- Insertion valves and line stops after a sheared 8-inch valve, Covington, Ohio
- Epoxy recoating of HDD-damaged girth and spiral welds, Kansas
- West Virginia 30-inch leak at a previous composite wrap
- Port Allen valve-station dent reinforced with an E-glass wrap
- 14-inch diesel line at Redding, Pennsylvania, carbon wrap
- Hinged protective tools on a 24-inch Florida line during bridge work
- Custom Type B sleeve around an existing clamp, Florida
- Type B sleeves replacing mechanical clamps at a Texas refinery
- Double-hump girth-weld sleeve on a 26-inch Kentucky gas line
- Compression sleeve on a crude line, Middle East operator
Spotted an error? Engineers keep this site honest.Report an error or suggest a correction