07 · Case studies
Subsea Clamp+Sleeve repair of a buckled 10-inch crude line, South Marsh Island Block 59
In short Custom 10-by-72-inch subsea Clamp+Sleeve engineered from a diver cast and 3D scan to reinforce a buckled Gulf of Mexico crude line.
Source: PLIDCO (The Pipe Line Development Company), with installation by Chet Morrison Contractors (2023). Account type: Vendor account.
In-line inspection found a buckle in Crimson Midstream’s 10-inch crude line in South Marsh Island Block 59. After BSEE required reinforcement, divers took a cast of the bent pipe, the shape was 3D-scanned, and PLIDCO built a custom 10-by-72-inch Clamp+Sleeve with a four-degree bend and clamping ends to take axial load, designed to ASME Section VIII for 1,500 psi. The fitting was set at about 130 feet of water, torqued, hydrotested with the line still in service, and the annulus was filled with a sealant. The vendor says the job took three days and 41 dives and was completed on the first try.
Method
Custom PLIDCO 10x72-inch Clamp+Sleeve with a four-degree horizontal bend, integral clamping ends, elastomer seals, and a hydraulic hinged closure; annulus later filled with Liquid Bridge Seal. Installed by divers; hydrotested on the live line.
Defect
Buckle / deflection found by in-line inspection, leaving a weakened cross-section. BSEE required structural reinforcement.
Pipe
10-inch crude-oil pipeline, Gulf of Mexico, South Marsh Island Area Block 59, Crimson Midstream. Fitting MAOP 1,500 psi; about 49 inches between seals. Installed at roughly 130 feet of water depth. Carrier-pipe grade not stated.
Outcome
PLIDCO reports the fitting was installed on the first attempt over about 41 dives and three days, hydrotested, and that the pipeline remained in service. This is a vendor case study.
Schedule, cost, and service-life figures in this note are the publisher’s claims. They were not checked against an operator record or a laboratory report.
Dates: Case-study PDF is dated September 2023 on the file path; the HTML version was posted 5 August 2025.
Maker named in the source: PLIDCO.
Sources
- Subsea Clamp+Sleeve repair of a buckled 10-inch crude line, South Marsh Island Block 59 — PLIDCO (The Pipe Line Development Company), with installation by Chet Morrison Contractors
- Related public record — PLIDCO (The Pipe Line Development Company), with installation by Chet Morrison Contractors
Related notes
- Mechanical and bolt-on clamps — Repair methods
- Advisory bulletins that bear on repair — Regulations and official guidance
- Temporary and permanent repairs — Regulations and official guidance
- ASME B31.4 — Codes and standards
- Type B steel sleeves — Repair methods
- Choosing a repair — Repair methods
Also in Case studies
- Type A sleeve leak on the Twin Oaks Pipeline, Upper Makefield Township, Pennsylvania
- Type B sleeve leak on the Marysville-Toledo Crude Pipeline, Sterling Heights, Michigan (CAO 4-2026-025)
- Type A sleeve leak on Colonial Line 1, Huntersville, North Carolina (CPF 2-2021-005-NOPSO)
- Type A sleeve leak on Colonial Line, Gwinnett County (Harbins Road), Georgia
- Type A sleeve leak on the CNG/Plantation pipeline, Belton, South Carolina
- Type C compression-sleeve repairs on the Oasis Pipeline, Texas
- In-service X70 Type B sleeve installation on West-East Gas Pipeline Line 3, China
- ROV-installed Flange Repair Split+Sleeve on a 10-inch water-injection line, offshore Angola
- ROV-installed leak-sealing clamp on a 10-inch water-injection riser flange, Foinaven field
- Emergency leak repair on a 30-inch onshore pipeline with a bolt-on fitting
- Composite sleeve repair of 900 feet of cooling-tower corrosion on a U.S. refinery pipeline
- Composite sleeve repair of a dent and seam-weld crack on a 24-inch crude-oil pipeline
- Underwater composite sleeve repair of girth-weld corrosion on a 12-inch gas pipeline
- Composite sleeve repair of a rockfall dent on a 36-inch hydroelectric pipeline in the French Alps
- Burst test of a composite sleeve repair recovered after 25 years in service (installed 1995)
- Composite pipe-wrap repairs of corrosion on Equistar Pipeline, Texas
- Weld-wrap composite reinforcement of an internal weld defect on a 24-inch products pipeline, Western Europe
- Composite repair of a 32-inch offshore riser, Thailand
- Splash-zone composite repair of mechanical damage on a 12-inch subsea crude line, Gulf of Mexico
- Carbon-fiber repair of a deep crack on a 900 mm gas-transmission bend
- Epoxy-filled sleeve encapsulation of a large dent on a 14-inch trunkline, Papua New Guinea
- High-pressure line-plug isolation to remove a stuck pig and replace a leaking valve on a CO2 pipeline
- Line-plug train isolation and diversion of two 24-inch gas transmission lines under a planned Singapore subway station
- Line-plug train isolation to decommission a gas-processing plant off a 36-inch transmission line, Alabama
- Emergency double line-plug isolation of a burning 14-inch NGL pipeline after a third-party strike, West Texas
- 12-inch double line-plug isolation with bypass for a live gas-line repair, Oklahoma
- Line stop to connect 8-inch PE gas mains, St. Louis
- Insertion valves and line stops after a sheared 8-inch valve, Covington, Ohio
- Epoxy recoating of HDD-damaged girth and spiral welds, Kansas
- West Virginia 30-inch leak at a previous composite wrap
- Port Allen valve-station dent reinforced with an E-glass wrap
- 14-inch diesel line at Redding, Pennsylvania, carbon wrap
- Hinged protective tools on a 24-inch Florida line during bridge work
- Custom Type B sleeve around an existing clamp, Florida
- Type B sleeves replacing mechanical clamps at a Texas refinery
- Double-hump girth-weld sleeve on a 26-inch Kentucky gas line
- Compression sleeve on a crude line, Middle East operator
Spotted an error? Engineers keep this site honest.Report an error or suggest a correction