07 · Case studies
Epoxy-filled sleeve encapsulation of a large dent on a 14-inch trunkline, Papua New Guinea
In short Custom enlarged-body epoxy-filled steel sleeve encapsulating a large landslide dent on a 14-inch trunkline in Papua New Guinea.
Source: PipeServ (RAMFILL). Account type: Vendor account.
A falling tree dented a highly productive 14-inch trunkline in Papua New Guinea and ovalized a wide stretch of pipe. A pre-cured composite sleeve had already been put on as an emergency repair. Because a cut-out would have stopped production, the operator, which had used epoxy-filled sleeves before, ordered a custom 3-metre epoxy-filled steel sleeve with an enlarged DN500 body to clear the dent. After the sleeve was welded and inspected, the annulus was filled with 100 percent-solids epoxy for load transfer, corrosion protection, and leak sealing. The supplier says the line stayed in service. This is one of the few public, detailed epoxy-filled-shell field jobs.
Method
Custom RAMFILL-B+RE epoxy-filled steel sleeve, 3.0 m long with an enlarged DN500 body, welded then filled with 100 percent-solids liquid epoxy. A Clock Spring wrap had been applied earlier as an emergency repair.
Defect
Large dent caused by a falling tree, with ovality over a wide area
Pipe
DN350 / 14-inch trunkline, Papua New Guinea. Design pressure and grade are described only as meeting the client’s specified design pressures and temperatures. The line could not be shut down.
Outcome
PipeServ reports the sleeve was welded, NDT-inspected, and epoxy-filled with the line remaining in service, and describes the repair as permanent with no production loss. Those claims are the supplier’s.
Schedule, cost, and service-life figures in this note are the publisher’s claims. They were not checked against an operator record or a laboratory report.
Dates: Year of the repair is not stated. The PDF path is dated January 2025.
Maker named in the source: PipeServ (RAMFILL); prior emergency wrap by Clock Spring / CSNRI.
Sources
Related notes
- Epoxy-filled sleeves — Repair methods
- Type A steel sleeves — Repair methods
- Dents — Defect assessment
- Advisory bulletins that bear on repair — Regulations and official guidance
- ASME B31.8 and B31.8S — Codes and standards
- Choosing a repair — Repair methods
Also in Case studies
- Type A sleeve leak on the Twin Oaks Pipeline, Upper Makefield Township, Pennsylvania
- Type B sleeve leak on the Marysville-Toledo Crude Pipeline, Sterling Heights, Michigan (CAO 4-2026-025)
- Type A sleeve leak on Colonial Line 1, Huntersville, North Carolina (CPF 2-2021-005-NOPSO)
- Type A sleeve leak on Colonial Line, Gwinnett County (Harbins Road), Georgia
- Type A sleeve leak on the CNG/Plantation pipeline, Belton, South Carolina
- Type C compression-sleeve repairs on the Oasis Pipeline, Texas
- In-service X70 Type B sleeve installation on West-East Gas Pipeline Line 3, China
- Subsea Clamp+Sleeve repair of a buckled 10-inch crude line, South Marsh Island Block 59
- ROV-installed Flange Repair Split+Sleeve on a 10-inch water-injection line, offshore Angola
- ROV-installed leak-sealing clamp on a 10-inch water-injection riser flange, Foinaven field
- Emergency leak repair on a 30-inch onshore pipeline with a bolt-on fitting
- Composite sleeve repair of 900 feet of cooling-tower corrosion on a U.S. refinery pipeline
- Composite sleeve repair of a dent and seam-weld crack on a 24-inch crude-oil pipeline
- Underwater composite sleeve repair of girth-weld corrosion on a 12-inch gas pipeline
- Composite sleeve repair of a rockfall dent on a 36-inch hydroelectric pipeline in the French Alps
- Burst test of a composite sleeve repair recovered after 25 years in service (installed 1995)
- Composite pipe-wrap repairs of corrosion on Equistar Pipeline, Texas
- Weld-wrap composite reinforcement of an internal weld defect on a 24-inch products pipeline, Western Europe
- Composite repair of a 32-inch offshore riser, Thailand
- Splash-zone composite repair of mechanical damage on a 12-inch subsea crude line, Gulf of Mexico
- Carbon-fiber repair of a deep crack on a 900 mm gas-transmission bend
- High-pressure line-plug isolation to remove a stuck pig and replace a leaking valve on a CO2 pipeline
- Line-plug train isolation and diversion of two 24-inch gas transmission lines under a planned Singapore subway station
- Line-plug train isolation to decommission a gas-processing plant off a 36-inch transmission line, Alabama
- Emergency double line-plug isolation of a burning 14-inch NGL pipeline after a third-party strike, West Texas
- 12-inch double line-plug isolation with bypass for a live gas-line repair, Oklahoma
- Line stop to connect 8-inch PE gas mains, St. Louis
- Insertion valves and line stops after a sheared 8-inch valve, Covington, Ohio
- Epoxy recoating of HDD-damaged girth and spiral welds, Kansas
- West Virginia 30-inch leak at a previous composite wrap
- Port Allen valve-station dent reinforced with an E-glass wrap
- 14-inch diesel line at Redding, Pennsylvania, carbon wrap
- Hinged protective tools on a 24-inch Florida line during bridge work
- Custom Type B sleeve around an existing clamp, Florida
- Type B sleeves replacing mechanical clamps at a Texas refinery
- Double-hump girth-weld sleeve on a 26-inch Kentucky gas line
- Compression sleeve on a crude line, Middle East operator
Spotted an error? Engineers keep this site honest.Report an error or suggest a correction