Line stop to connect 8-inch PE gas mains, St. Louis
In short Mechanical line stop through a hot-tap fitting on an 8-inch polyethylene gas distribution main in St. Louis without pipe squeezing.
Source: Mueller Water Products, quoting Spire Energy (2020). Account type: Vendor account.
Spire Energy needed to connect an 8-inch, 25 psi polyethylene gas main in St. Louis to a new 8-inch, 60 psi main, and did not want to squeeze the PE pipe. With no isolation valves in the area, the company used a line stopper, inserted through a hot-tap fitting, to get a full stop-off, then cut and tied in only part of the low-pressure system. After the work, the stopper was removed and the tap was sealed with an integral plug. This is a distribution-system case, not a transmission-line job, but it is a named-utility example of a mechanical line stop on PE gas pipe.
Method
Hot-tap-installed Shur Stop line stopper on polyethylene gas pipe, used instead of squeeze-off; stopper later removed and the tap sealed with an integral plug
Defect
Not a defect repair. Planned tie-in of a low-pressure PE main to a higher-pressure PE main where no isolation valves existed and the utility did not want to squeeze the pipe.
Pipe
Existing 8-inch PE main at 25 psi, to be connected to a new 8-inch PE main at 60 psi, St. Louis, Missouri, Spire Energy.
Outcome
Spire’s drill-and-stop supervisor is quoted as saying the stop-off was faster and more reliable than squeezing. Part of the low-pressure system was tied in; the remainder was capped and left at 25 psi.
Schedule, cost, and service-life figures in this note are the publisher’s claims. They were not checked against an operator record or a laboratory report.
Dates: Article dated 1 April 2020.
Maker named in the source: Mueller (Shur Stop).
Sources
- Mueller Shur Stop line stop to connect 8-inch PE gas mains, St. Louis — Mueller Water Products, quoting Spire Energy
Related notes
- Hot tapping and line plugging — Repair methods
- In-service welding and hydrogen pipelines — Repair methods
- Cut-out and replacement — Repair methods
- ASME B31.8 and B31.8S — Codes and standards
- Part 192 repair and integrity duties — Regulations and official guidance
- Choosing a repair — Repair methods
Also in Case studies
- Type A sleeve leak on the Twin Oaks Pipeline, Upper Makefield Township, Pennsylvania
- Type B sleeve leak on the Marysville-Toledo Crude Pipeline, Sterling Heights, Michigan (CAO 4-2026-025)
- Type A sleeve leak on Colonial Line 1, Huntersville, North Carolina (CPF 2-2021-005-NOPSO)
- Type A sleeve leak on Colonial Line, Gwinnett County (Harbins Road), Georgia
- Type A sleeve leak on the CNG/Plantation pipeline, Belton, South Carolina
- Type C compression-sleeve repairs on the Oasis Pipeline, Texas
- In-service X70 Type B sleeve installation on West-East Gas Pipeline Line 3, China
- Subsea Clamp+Sleeve repair of a buckled 10-inch crude line, South Marsh Island Block 59
- ROV-installed Flange Repair Split+Sleeve on a 10-inch water-injection line, offshore Angola
- ROV-installed leak-sealing clamp on a 10-inch water-injection riser flange, Foinaven field
- Emergency leak repair on a 30-inch onshore pipeline with a bolt-on fitting
- Composite sleeve repair of 900 feet of cooling-tower corrosion on a U.S. refinery pipeline
- Composite sleeve repair of a dent and seam-weld crack on a 24-inch crude-oil pipeline
- Underwater composite sleeve repair of girth-weld corrosion on a 12-inch gas pipeline
- Composite sleeve repair of a rockfall dent on a 36-inch hydroelectric pipeline in the French Alps
- Burst test of a composite sleeve repair recovered after 25 years in service (installed 1995)
- Composite pipe-wrap repairs of corrosion on Equistar Pipeline, Texas
- Weld-wrap composite reinforcement of an internal weld defect on a 24-inch products pipeline, Western Europe
- Composite repair of a 32-inch offshore riser, Thailand
- Splash-zone composite repair of mechanical damage on a 12-inch subsea crude line, Gulf of Mexico
- Carbon-fiber repair of a deep crack on a 900 mm gas-transmission bend
- Epoxy-filled sleeve encapsulation of a large dent on a 14-inch trunkline, Papua New Guinea
- High-pressure line-plug isolation to remove a stuck pig and replace a leaking valve on a CO2 pipeline
- Line-plug train isolation and diversion of two 24-inch gas transmission lines under a planned Singapore subway station
- Line-plug train isolation to decommission a gas-processing plant off a 36-inch transmission line, Alabama
- Emergency double line-plug isolation of a burning 14-inch NGL pipeline after a third-party strike, West Texas
- 12-inch double line-plug isolation with bypass for a live gas-line repair, Oklahoma
- Insertion valves and line stops after a sheared 8-inch valve, Covington, Ohio
- Epoxy recoating of HDD-damaged girth and spiral welds, Kansas
- West Virginia 30-inch leak at a previous composite wrap
- Port Allen valve-station dent reinforced with an E-glass wrap
- 14-inch diesel line at Redding, Pennsylvania, carbon wrap
- Hinged protective tools on a 24-inch Florida line during bridge work
- Custom Type B sleeve around an existing clamp, Florida
- Type B sleeves replacing mechanical clamps at a Texas refinery
- Double-hump girth-weld sleeve on a 26-inch Kentucky gas line
- Compression sleeve on a crude line, Middle East operator
Spotted an error? Engineers keep this site honest.Report an error or suggest a correction