07 · Case studies
Splash-zone composite repair of mechanical damage on a 12-inch subsea crude line, Gulf of Mexico
In short Diver-applied underwater carbon-fiber wrap with splashzone resin repairing two meters of mechanical damage on a 12-inch Gulf crude line.
Source: IAS Group / IC Integrity (Technowrap). Account type: Vendor account.
A 12-inch crude line in the Gulf of Mexico had external mechanical damage on a two-metre stretch, 12 feet below the surface. An engineered layer count was prepared for a 20-year design life at 75.8 bar. Divers bristle-blasted the pipe to St 3 and applied a carbon-fibre composite with a splash-zone resin, which is formulated to cure underwater. The contractor says the line was not shut down and no hot work was used. The page also points to a PRCI research program on subsea composite repairs, which is useful context, but the field job itself is a vendor summary.
Method
Technowrap Structural Rehabilitation System (carbon fibre) with Technowrap Splashzone resin, applied by divers after bristle-blasting to St 3. The page also notes a 15-month PRCI-led research program on subsea composite repairs.
Defect
External mechanical damage on a 2-metre section
Pipe
12-inch (323.8 mm) crude-oil pipeline, 12 feet below sea level in the Gulf of Mexico. Design pressure 75.8 bar, design temperature 38 C, application temperature 10 C, 20-year design life. Wrap length is listed as 5,000 mm in the project table.
Outcome
The vendor reports no hot work and no shutdown, with flow maintained. No independent test results are given on this page.
Schedule, cost, and service-life figures in this note are the publisher’s claims. They were not checked against an operator record or a laboratory report.
Dates: Year not stated.
Maker named in the source: Technowrap (IC Integrity / IAS Group).
Sources
- Technowrap Splashzone repair of mechanical damage on a 12-inch subsea crude line, Gulf of Mexico — IAS Group / IC Integrity (Technowrap)
Related notes
- Composite wraps — Repair methods
- ASME PCC-2 — Codes and standards
- ISO 24817 — Codes and standards
- Corrosion metal loss — Defect assessment
- AB-539: engineered composite alterations in Alberta — Regulations and official guidance
- Choosing a repair — Repair methods
Also in Case studies
- Type A sleeve leak on the Twin Oaks Pipeline, Upper Makefield Township, Pennsylvania
- Type B sleeve leak on the Marysville-Toledo Crude Pipeline, Sterling Heights, Michigan (CAO 4-2026-025)
- Type A sleeve leak on Colonial Line 1, Huntersville, North Carolina (CPF 2-2021-005-NOPSO)
- Type A sleeve leak on Colonial Line, Gwinnett County (Harbins Road), Georgia
- Type A sleeve leak on the CNG/Plantation pipeline, Belton, South Carolina
- Type C compression-sleeve repairs on the Oasis Pipeline, Texas
- In-service X70 Type B sleeve installation on West-East Gas Pipeline Line 3, China
- Subsea Clamp+Sleeve repair of a buckled 10-inch crude line, South Marsh Island Block 59
- ROV-installed Flange Repair Split+Sleeve on a 10-inch water-injection line, offshore Angola
- ROV-installed leak-sealing clamp on a 10-inch water-injection riser flange, Foinaven field
- Emergency leak repair on a 30-inch onshore pipeline with a bolt-on fitting
- Composite sleeve repair of 900 feet of cooling-tower corrosion on a U.S. refinery pipeline
- Composite sleeve repair of a dent and seam-weld crack on a 24-inch crude-oil pipeline
- Underwater composite sleeve repair of girth-weld corrosion on a 12-inch gas pipeline
- Composite sleeve repair of a rockfall dent on a 36-inch hydroelectric pipeline in the French Alps
- Burst test of a composite sleeve repair recovered after 25 years in service (installed 1995)
- Composite pipe-wrap repairs of corrosion on Equistar Pipeline, Texas
- Weld-wrap composite reinforcement of an internal weld defect on a 24-inch products pipeline, Western Europe
- Composite repair of a 32-inch offshore riser, Thailand
- Carbon-fiber repair of a deep crack on a 900 mm gas-transmission bend
- Epoxy-filled sleeve encapsulation of a large dent on a 14-inch trunkline, Papua New Guinea
- High-pressure line-plug isolation to remove a stuck pig and replace a leaking valve on a CO2 pipeline
- Line-plug train isolation and diversion of two 24-inch gas transmission lines under a planned Singapore subway station
- Line-plug train isolation to decommission a gas-processing plant off a 36-inch transmission line, Alabama
- Emergency double line-plug isolation of a burning 14-inch NGL pipeline after a third-party strike, West Texas
- 12-inch double line-plug isolation with bypass for a live gas-line repair, Oklahoma
- Line stop to connect 8-inch PE gas mains, St. Louis
- Insertion valves and line stops after a sheared 8-inch valve, Covington, Ohio
- Epoxy recoating of HDD-damaged girth and spiral welds, Kansas
- West Virginia 30-inch leak at a previous composite wrap
- Port Allen valve-station dent reinforced with an E-glass wrap
- 14-inch diesel line at Redding, Pennsylvania, carbon wrap
- Hinged protective tools on a 24-inch Florida line during bridge work
- Custom Type B sleeve around an existing clamp, Florida
- Type B sleeves replacing mechanical clamps at a Texas refinery
- Double-hump girth-weld sleeve on a 26-inch Kentucky gas line
- Compression sleeve on a crude line, Middle East operator
Spotted an error? Engineers keep this site honest.Report an error or suggest a correction